MZL-1024
24v 30 amp
STARTS TIMING WHEN IGNITION TURNS OFF.
DIAGRAM
TIMER SWITCH SETTINGS
- FEATURES
- SPECIFICATIONS
- Battery guard system
- Emergency override switch provides a convenient way to restore power to your equipment by holding the button in.
- Protects communication equipment
- Low voltage detector (19 v)
- Over voltage protection (30 v)
- Automatic On/Off
- Very reliable & accurate
- Programmable with external DIP switch for selecting and adjusting time delay
- Built-in diagnostic red LED indicates timing functions active when flashing
- Engineered electronically for reverse polarity protection
- Potted compound construction. Solid state, sealed against vibration and moisture.
- Easy external connection with .250 male tab mating with .250 female disconnect
- Delay time range: from 15 seconds to 8 hours. Tolerance plus (+) or minus (-) 10%
- Allow 3-5 seconds for delay on break at ignition switch connection for delay activation
- For installation, connect both .250 male tabs (+) to the battery positive post and .250 male tab (-) to the battery negative post. Connect the ignition switch .250 male tab to fuse block (AM/FM radio) or cigarette lighter.
Technical Specifications
Electrical Specifications
| Length | 4 in. |
| Width | 2 in. |
| Height | 1.5 in. |
| Mounting Hole Center | 3.5in with #6 screws |
| Weight | 6 oz. |
| Enclosure Material | Impact Resistant ABS thermoplastic |
Electrical Specifications
| Load Current Rate | 30 amps 24 VDC |
| Operating Voltage | 18 VDC min - 33 VDC max |
| Ignition Switch Trigger | 10.4 - 15.0 VDC, 10mA |
| Low Voltage Disconnect | 19 volts |
| Over Voltage Disconnect | 30 volts |
| Operating Temperature | -40 F to +185 F |
| Stand-by Current | 6 mA |
| Operating Current | 100 mA |
Caution: An appropriate size fuse circuit breaker must be used to ensure safety.