FEATURES
- Emergency override switch provides a convenient way to restore power to your equipment by holding the button in for 5-8 seconds.
- Protects communication equipment
- Automatic On/Off
- Very reliable & accurate
- Programmable with external DIP switch for selecting and adjusting time delay
- Built-in diagnostic red LED indicates timing functions active when flashing
- Engineered electronically for reverse polarity protection
- Potted compound construction. Solid state, sealed against vibration and moisture.
- Delay time range: from 15 minutes to 8 hours. Tolerance plus (+) or minus (-) 10%
- Allow 3-5 seconds for delay on break at ignition switch connection for delay activation
- For installation, connect the red wire (+) to the battery positive post and the black wire (-) to the battery negative post. Connect the blue wire to fuse block (AM/FM radio) or cigarette lighter.
SPECIFICATIONS
Technical Specifications
| Length | 4.25 in. |
| Width | 3 in. |
| Height | 1.375 in. |
| Mounting Hole Center | 5.250 x 2.250 |
| Weight | 15 oz. |
| Enclosure Material | Impact Resistant ABS thermoplastic |
Electrical Specifications
| Load Current Rate | 30 amps 12 VDC |
| Operating Voltage | 10 VDC min - 18 VDC max |
| Ignition Switch Trigger | 10.4 - 15.0 VDC, 10mA |
| Low Voltage Disconnect | 10.5 |
| Over Voltage Disconnect | 17 volts |
| Operating Temperature | -40 F to +185 F |
| Stand-by Current | 6 mA |
| Operating Current | 100 mA |
Caution: An appropriate size fuse circuit breaker must be used to ensure safety.